MMK/MML | MULTI-STAGE TURBINE PUMPS | TORISHIMA PUMP

MMK/MML | MULTI-STAGE TURBINE PUMPS | TORISHIMA


At MMK, the axial thrust is balanced by the impeller balance hole
At MML, the axial thrust is balanced by the balance disk.

FEATURES
1.  Mounting available either below the pump or at centerline
2.  High efficiency impeller
3.  Absorption of unbalanced axial thrust by balancing hole for MMK, and by balancing device for MML
4.  Renewable shaft protecting sleeve
5.  Uncooled packing stuffing box for operating temperature 105 Degree Celsius
6.  Variety of nozzle orientation

TECHNICAL DATA
Total Head     :  up to 420 m
Capacity        :  up to 240 m3/hr
Size              :  40 to 150 mm
Temperature  :  up to 105 Degree Celsius (non cooling type)
                       up to 180 Degree Celsius (cooling type)

BENEFITS
1.  Better axial thrust absorption
2.  Assured high efficiency (low operational cost)
3.  Wide range application
4.  Flexible application
5.  Eliminate of cooling water free for operation up to 105 Degree Celsius

APPLICATIONS
Used for general clean water supply duty and in the industry as a boiler feed pump, condensate pump, power water pump, pressure water pump, cooling water pump, hot water circulation pump, etc

CDM | HORIZONTAL SPLIT CASE DOUBLE SUCTION PUMPS | TORISHIMA

CDM | HORIZONTAL SPLIT CASE DOUBLE SUCTION PUMPS | TORISHIMA


CDM designed with the most advanced hydraulic profiles. Providing less noise and vibration, wider operating range, lower NPSH, required and higher efficiency.

FEATURES
1.  High efficiency impeller three-dimensional double suction impeller
2.  Horizontal split volume casing designed in accordance with finite element construction analysis
3.  Easily fitted casing wear ring and shaft sleeves
4.  Easily maintenance grease lubricated bearing as standard
5.  Soft-packed stuffing box as standard

TECHNICAL DATA
Total Head      H    up to 180 m
Capacity         Q    up to 4800 m3/hr
Size              DN   200 to 700 mm
Temperature   T    up to 80 Degree Celsius
Available option with vertical construction

BENEFITS
1.  Assured high efficiency (low operational cost)
2.  High speed, compact and light weight design
3.  Stable curve characteristics
4.  Low NPSH required
5.  Low noise and vibration
6.  Easy maintenance (quick repair work)

APPLICATIONS
Water Intake, Distribution, Boosting, Circulating, Drainage, Fire Fighting, Cooling, Irrigation for Clean Water, Raw Water, Sea Water, Oil, etc.